like International Crystal on Facebook Join International Crystal on LinkedIn

New Products

 

opticlear

Opticlear™ Optical Cleaning Suspension

Opticlear™ is a suspension based cleaning system that peels contamination off the face of optics. It can be used on both coated and uncoated optics.
Availability & Estimated Shipping Date | Order NOW | more info...

Cadmium Manganese Telluride (CdMnTe) Magneto Optical Crystals
4" Diameter Polished SS Platen

4" Diameter 316SS Polymer Film Pressing Platens

The 4" diameter polished platens are useful for making large diameter polymer films. The platens are made from 1/2" thick 316SS. Platen surfaces are polished to a mirror finish.
Availability & Estimated Shipping Date | Order NOW | more info...

polyethylene sheets

Polyethylene Sheets

Polyethylene is a useful transmission material for far infrared sampling. Polyethylene is non-absorbing between 16 and 2500 microns.
Availability & Estimated Shipping Date | Order NOW | more info...

water jacketed dies

Water Jacketed Dies for Heating & Cooling Solid Samples

Water jacketed dies enable heating and cooling of samples under force. These dies are available with 5mm to 40mm diameter anvils.
Availability & Estimated Shipping Date | Order NOW | more info...

heated variable pathlength cell

Sealed Liquid Spectrophotometer Cells - ICL Heated Variable Pathlength Cell

The heated variable pathlength cell can be heated to 200° C and comes complete with a programmable ramp and soak temperature controller with RS-232 serial cable computer interface.
Availability & Estimated Shipping Date | Order NOW | more info...

cover slips

Cover Slips for Mass Spectrometer Dating Analysis of Mineral Gases using CO2 Laser Stimulation

KBr cover slips for samples heated in highly pressurized chambers by CO2 lasers to liberate entrapped gases such as Argon from minerals and other natural samples for 40Ar-39Ar dating using a mass spectrometer.
Availability & Estimated Shipping Date | Order NOW | more info...

European Pharmacopoeia 2.2.24 Reference Standard

ICL's PhEur 2.2.24 Reference Standard is a calibration standard certified to conform to the requirements of Chapter 2.2.24 of the European Pharmacopoeia.
Availability & Estimated Shipping Date | Order NOW | more info...

Pharmaceutical Active Ingredients Intrinsic Dissolution Rate Kit

ICL's new dissolution kit enables testing of the intrinsic dissolution rate of active pharmaceutical ingredients.
Availability & Estimated Shipping Date | Order NOW | more info...

Transmission Sampling Kits

ICL's transmission sampling kits contain a comprehensive array of sampling accessories for solid, liquid and gas sampling. Contact ICL or consult the catalog for a comprehensive description of the contents of each kit.
Availability & Estimated Shipping Date | Order NOW | more info...

Reflectance Sampling Kits

ICL offers two reflective sampling kits. Each contains a Mini “D” Diffuse Reflection Accessory, a 30° Specular Reflection Accessory and either a single bounce or multiple bounce HATR. Part No. 0000-7429 contains ICL's Basics™ HATR (Part No. 0015-4713). Part No. 0000-7430 contains ICL's High Energy Universal Sampler HATR (0015-7458). Specify instrument and flat or trough top plate.
Availability & Estimated Shipping Date | Order NOW | more info...

High Energy Universal Sampler HATR

This new single reflection Horizontal ATR has the highest energy throughput of any ATR accessory on the market today.
Availability & Estimated Shipping Date | Order NOW | more info...

Split Pea™ Hemi Micro HATR Sampler

The Split Pea™ Hemi Micro ATR Sampler has the smallest sampling area of any ATR accessory.
Availability & Estimated Shipping Date | Order NOW | more info...

1 & 2 Ton E-Z Presses™

ICL's 1 & 2 Ton E-Z Presses™ feature the same unibody construction and features common to our E-Z Press™ line, but we have redesigned these presses to maximize the sensitivity of the press for exact reproducibility of applied force.
Availability & Estimated Shipping Date | Order NOW | more info...

Polystyrene Calibration Films on KBr Windows

In addition to standard polystyrene calibration films, ICL offers several other calibration options. Superior calibrations are performed with radially symmetric films which eliminate the orientation effects of extruded films used for NIST Standard 1921 calibrations.
Availability & Estimated Shipping Date | Order NOW | more info...

Stainless Steel & Nickel Plated Aluminum Long Path Gas Cells

ICL’s all metal gas cells are available in stainless steel and electroless nickel plated aluminum. The cells are designed for mounting in a center focus FTIR. Optics are mounted on removable sub-assemblies.
Availability & Estimated Shipping Date | Order NOW | more info...

G-3PTFE 10cm Teflon PTFE Gas Cell

All components of the G-3PTFE 10cm gas cell that contact the sample can be made entirely of Teflon® PTFE, making the cell useful for any gas sample that might attack, or be contaminated by, glass or stainless steel gas cell components. The G-3PTFE is useful for analysis of pure gases and mixtures in which the constituent gases are present in concentrations of 5% or more.
Availability & Estimated Shipping Date | Order NOW | more info...

E-Z™ Quick Table Top KBr Pellet Press

The E-Z™ Quick Table Top Press operates on the same toggle action principle as our Quick Press
Availability & Estimated Shipping Date | Order NOW | more info...

2 Ton High Profile E-Z Press™

The 2 ton high profile E-Z Press™ incorporates the same wine press design as our standard 1 and 2 ton presses (0012-7417 & 0012-7760), but it also has a larger 5 ¼”  daylight opening and a larger sample compartment to enable use of the press with Wood apparatus intrinsic dissolution dies and other applications requiring a larger daylight opening.

Availability & Estimated Shipping Date | Order NOW | more info...

Digital Load Cell E-Z Press

The Digital Load Cell E-Z Press™ provides real time calibrated force readings displayed in a large, bright digital readout.   These laboratory presses are available in 1000 and 5000 pound versions.

Availability & Estimated Shipping Date | Order NOW | more info...

Wood Intrinsic Dissolution Apparatus

The Wood apparatus for intrinsic dissolution testing was originally developed by Dr. John Wood in 1963. The apparatus enables the calculation of the dissolution rate per centimeter squared of the intrinsic ingredients of pharmaceutical products. ICL has brought its extensive experience in the manufacture of dies and presses for laboratory applications to bear to produce an improved version of the Wood intrinsic dissolution apparatus.

Availability & Estimated Shipping Date | Order NOW | more info...